Skip to content

MINSTED Nanoscopy: Tracking Single Proteins in Crowded Living Cells

MINSTED nanoscopy uses laser beams to locate single proteins in three dimensions. A new setup may follow them even in crowded living cells.

MINSTED nanoscopy is a light-microscope method that pinpoints single fluorescent molecules with nanometer precision. Biologists want such precision because proteins do their work by moving and changing shape. Watching one protein inside a living cell, however, has been difficult. Cells are crowded, and glowing neighbors can drown out the molecule of interest. A team led by Stefan Hell in Germany now reports a three-dimensional version. Their setup followed individual motor proteins as they walked through living cells. This explainer describes the problem, the optical idea, and what the measurements show. It also looks at where such tools could lead in research, education, and careers.

The work appears in Nature Communications, where Peters and colleagues describe the instrument in detail. Earlier MINSTED nanoscopy had tracked single proteins only in two dimensions and outside living cells. The new study adds the third dimension and moves into living cells. Its authors report localizing a molecule to better than one nanometer under favorable conditions. For scale, a nanometer is one millionth of a millimeter. The test case was kinesin-1, a protein that hauls cargo along tracks inside the cell. Its regular 16-nanometer steps make it a convenient ruler for any tracking method. A method that resolves those steps in a crowded cell has passed a demanding test.

Why Tracking One Protein in a Living Cell Is Hard

Researchers make a protein visible by attaching a fluorophore, which glows under laser light. Diffraction makes ordinary microscopes blur that glow into a spot far larger than the protein. Methods grouped as super-resolution microscopy get around the blur in different ways. One of them, MINFLUX, probes the molecule with a beam that has a dark center. The closer the dark center sits to the molecule, the less the molecule glows. By steering the beam and watching the signal fall, the instrument narrows down the position. The authors note that it needs about 100 times fewer detected photons than camera-based localization. Schmidt and colleagues showed in 2021 that a standard microscope stand could host it.

The dark-centered beam has a drawback, though. Its bright, donut-shaped rim lights up a much larger volume than a normally focused beam. Any other fluorophore sitting in that rim also glows and adds unwanted background. In a crowded cell, the paper explains, such neighbors can easily outshine the target. The problem grows as the dark center closes in, because the target’s signal keeps shrinking. Researchers therefore label only a sparse handful of proteins. That sparse labeling is hard to control in living cells, the authors write. As a result, tracking with nanometer and millisecond resolution in crowded cells remained challenging. MINSTED nanoscopy offers a different way of defining the measurement spot.

How MINSTED Nanoscopy Carves Out One Signal

MINSTED nanoscopy turns the arrangement around. It excites fluorophores with an ordinary focused pulse, then follows with a second, donut-shaped pulse. The second pulse relies on stimulated emission depletion, or STED, to switch fluorescence off. Only molecules near the donut’s dark center can still glow. In effect, the STED beam carves a tiny measurement spot out of the excited region. The authors calculate a spot about 30 times smaller in volume than in three-dimensional MINFLUX. A smaller spot leaves less room for interfering neighbors. Earlier work by Weber and colleagues had shown how far the idea reaches. With 2,000 detected photons, they localized fluorophores on DNA to within 0.47 nanometers.

The new instrument extends that principle to depth. Green excitation pulses at 532 nanometers last 200 picoseconds. Red STED pulses at 636 nanometers then follow for 1.5 nanoseconds. Three STED beams take turns. One donut circles the molecule’s estimated position in the focal plane 125,000 times per second. Two further beams form hollow, bottle-like shapes placed slightly above and slightly below that plane. When the detector registers a photon, the aim shifts toward the beam that produced it. The combined focus thus keeps circling around the molecule until the fluorophore fades. Each detected photon, in other words, nudges the estimate a little closer. The researchers call the full scheme 3D-MINSTED.

* Original illustration prepared for ENTECH Magazine; values from Peters and colleagues (2026).

Four labels around a focal spot: 532 nm excitation, 636 nm STED, 30x smaller volume and interleaved 3D donuts
Fig. 1: Laser beams used in 3D-MINSTED

Testing 3D-MINSTED on a DNA Ruler

Before turning to cells, the team checked the instrument against a structure of known size. They used DNA origami, in which strands of DNA fold into a designed shape. Each test grid carried nine binding sites in a three-by-three pattern. The manufacturer specified spacings of 10.9 and 12 nanometers between neighboring sites. Short fluorescent DNA strands docked briefly at the sites, and the microscope localized each one. From 87 grids, the measured median spacings were 10.6 and 9.6 nanometers. This first value matches the manufacturer’s specification closely. The authors attribute the shorter second value to salt, which can make such structures curl. Many grids lay tilted, so the microscope had to resolve them in three dimensions.

The same data set gave an estimate of precision. Because every detected photon adds information, precision improves as more photons arrive. By that analysis, 1,000 detected photons gave precision below one nanometer in one direction. That figure applies to a stationary molecule held on a DNA scaffold. A moving protein in a cell gives the instrument far fewer photons per position. Even so, the test showed that the three beams work together as intended. It also separated sites less than 10 nanometers apart, whatever their orientation in space. With the ruler confirmed, the group moved on to a protein that actually moves.

* Original illustration prepared for ENTECH Magazine; values from Peters and colleagues (2026).

Four labels around a nine-site grid: 87 origami grids, 10.6 nm spacing, 1000 photon precision and below 1 nm
Fig. 2: DNA origami test of the microscope

Following Kinesin Step by Step

Kinesin-1 is a motor protein that carries cargo along microtubules, stiff filaments inside the cell. It consumes the cell’s fuel molecule, ATP, and advances by a hand-over-hand walk. One of its two heads swings past the other and binds farther along the filament. A label on one head therefore moves about 16 nanometers at a time. Earlier, Scheiderer and colleagues had resolved such steps on artificial microtubules in two dimensions. The new work first repeated the measurement in three dimensions inside fixed, chemically preserved cells. From 1,440 recorded tracks, an automatic filter kept 188 for analysis. Those tracks contained 788 clear steps with a mean length of 16.7 nanometers.

Living cells were the harder test. The researchers made cells produce extra tagged kinesin, then attached a dye to the tag. Labeling was dense, with more than one fluorophore inside an ordinary focused beam’s sampling volume. Such density normally rules out single-molecule tracking, since two emitters spoil the position estimate. Despite this, the microscope recorded more than 10,000 tracks across four cells. Automatic selection kept 337 of them, containing 1,207 steps. The mean step length was again 16.7 nanometers, which agrees with earlier MINFLUX results. Signal exceeded background by a median ratio of 10.8. By their estimate, the method tolerates roughly 20 times denser labeling than commercial MINFLUX trackers.

* Original illustration prepared for ENTECH Magazine; values from Peters and colleagues (2026).

Four labels around a motor protein on a filament: 337 valid tracks, 1207 resolved steps and a 10.8 median SBR
Fig. 3: Kinesin tracking results in living cells

What 3D-MINSTED Could Change for Research and Careers

Tolerance for dense labeling has a practical side. When many labeled proteins share a field of view, more usable tracks arrive per hour. The team reports several hundred valid tracks from a single day of measurement. Sample preparation may also become simpler, because cells need not be labeled so sparingly. If the approach matures, laboratories could study motors, receptors, and enzymes in their crowded surroundings. That prospect could disrupt how instrument makers weigh the two competing designs. Drug researchers might likewise watch how a candidate compound alters a single protein’s motion. Such uses remain possibilities, since the study demonstrates one protein in one cell type. ENTECH has also covered label-free imaging of living cells, which avoids fluorescent tags altogether.

For students, MINSTED nanoscopy is a tour of several subjects at once. Lasers, polarization, and diffraction come from optics. Fluorescence and stimulated emission come from quantum physics. Motor proteins, microtubules, and ATP come from cell biology. Fast electronics, meanwhile, must coordinate pulses that last billionths of a second. Building such a microscope therefore draws on optical engineers, physicists, biochemists, and software developers. Data analysts also play a part, because an algorithm sorted the tracks instead of people. People with those skills work in university laboratories, instrument companies, and imaging facilities. Entrepreneurs may find room in components, analysis software, or measurement services. Readers curious about other molecular machines can explore DNA loop extrusion in a related explainer.

Limits and Open Questions

The authors are direct about what still falls short. Depth precision lagged behind sideways precision. For moving kinesin, they report 4.8 and 4.4 nanometers sideways but 11.7 nanometers in depth. They trace the gap to limited pulse energy in the two depth-confining lasers. Stronger lasers could narrow it, they suggest. Bleaching sets another limit, because the tracked fluorophore eventually stops glowing. The longest track in the study lasted 2.4 seconds. Time resolution stood at 2.4 milliseconds, and the analysis excluded steps too quick to resolve. In addition, the instrument is complex, with three separate STED lasers. The team proposes a simpler design built around a single one.

* Original illustration prepared for ENTECH Magazine; values from Peters and colleagues (2026).

Four labels around a focal spot: 11.7 nm axial, 0.4 nJ limit, STED bleaching cutoff and 2.4 s maximum
Fig. 4: Current limits of the 3D instrument

Several broader questions remain open. The demonstration involved one motor protein, one cell line, and one research group. Whether the method performs as well on slower, smaller, or membrane-bound proteins is untested here. The comparison with MINFLUX also rests partly on calculation, so side-by-side experiments would help. Independent laboratories will need access to similar instruments before the findings can be reproduced. Even so, the central idea is easy to state. Switching off unwanted fluorescence, instead of avoiding it, may let researchers work in crowded cells. That idea gives MINSTED nanoscopy a distinct place among tools for watching molecular life. Future studies could show how far it extends.

* Original illustration by ENTECH Magazine; values from Peters and colleagues (2026).

Four numbered key points: 3D tracking in living cells, 16.7 nm mean step, 20 times denser labeling, 2.4 ms time resolution
Fig. 5: Key points of the tracking study

References

Peters, J. B., Heidebrecht, C., Weber, M., Leutenegger, M., & Hell, S. W. (2026). 3D-MINSTED nanoscopy and protein tracking in densely labelled living cells. Nature Communications, 17, 11965. https://doi.org/10.1038/s41467-026-79580-9

Scheiderer, L., von der Emde, H., Hesselink, M., Weber, M., & Hell, S. W. (2024). MINSTED tracking of single biomolecules. Nature Methods, 21, 569–573. https://doi.org/10.1038/s41592-024-02209-6

Weber, M., von der Emde, H., Leutenegger, M., Gunkel, P., Sambandan, S., Khan, T. A., Keller-Findeisen, J., Cordes, V. C., & Hell, S. W. (2023). MINSTED nanoscopy enters the Ångström localization range. Nature Biotechnology, 41, 569–576. https://doi.org/10.1038/s41587-022-01519-4

Schmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W. (2021). MINFLUX nanometer-scale 3D imaging and microsecond-range tracking on a common fluorescence microscope. Nature Communications, 12, 1478. https://doi.org/10.1038/s41467-021-21652-z


Reviewed by Anupma Harshal on November 27, 2026Edited by Juveriya Khan
Reviewer note

This article introduces how a laser microscope can follow one labeled protein and why crowded cells make that difficult. It then explains how a second beam switches off unwanted glow, and what tests on a DNA ruler and a motor protein showed. A later revision could add a short comparison of related imaging methods, and further studies on other proteins would show how widely the approach applies.

Editorial note

Proteins carry out their tasks by moving, and seeing one of them at work inside a living cell has long strained the limits of light microscopy. This article explains a laser-based method that may make such observations possible in crowded cells, using a walking motor protein as the example. The papers and pages under References hold the full methods and measurements. Readers are encouraged to consult them and to check each claim for themselves. ENTECH accepts no responsibility for statements made here or in those sources. This article is offered for information and education only, and it is not professional advice.

Abdul Qadir
Abdul QadirPhysics Educator
Author

I am a Physics graduate with a strong academic interest in statistical mechanics, complex systems, computational physics, and the study of collective behaviour in interacting systems. During my undergraduate studies, I developed an interest in understanding physical phenomena not only through theoretical concepts but also through computational modelling and simulation. As part of my academic work, I explored the Ising model using Monte Carlo simulations and studied the Active Ising Model to investigate collective behaviour, density variations, and phase transitions in active systems. These projects introduced me to computational approaches in physics and strengthened my interest in understanding how simple microscopic interactions can give rise to complex macroscopic behaviour. Alongside my academic interests, I am passionate about education and science communication. I have experience helping students and peers understand concepts in physics and mathematics, with an emphasis on intuitive explanations rather than simply memorising formulas. I enjoy connecting scientific ideas to everyday experiences and presenting complex topics in a way that is clear, engaging, and accessible. I am also interested in the role of technology in education and the development of digital learning resources. Through writing, teaching, and educational projects, I hope to contribute to making scientific knowledge more accessible to students and curious learners. My broader interests include non-equilibrium statistical mechanics, active matter, phase transitions, computational modelling, complex systems, and science education. Through my work, I aim to continue developing as a researcher while contributing to science communication and education.

github.com/Abdulqadir-physics

Disclaimer.